登录    注册    忘记密码

详细信息

镀银聚酰胺6/聚酰胺6纳米纤维包芯纱电容传感器的构筑  ( EI收录)  

Construction of capacitive sensor based on silver coated polyamide 6/polyamide 6 nanofiber core-spun yarn

文献类型:期刊文献

中文题名:镀银聚酰胺6/聚酰胺6纳米纤维包芯纱电容传感器的构筑

英文题名:Construction of capacitive sensor based on silver coated polyamide 6/polyamide 6 nanofiber core-spun yarn

作者:范梦晶[1];吴玲娅[1];周歆如[1];洪剑寒[1,2];韩潇[1,2];王建[1,2]

机构:[1]绍兴文理学院纺织服装学院,浙江绍兴312000;[2]浙江省清洁染整技术研究重点实验室,浙江绍兴312000

年份:2023

卷号:44

期号:11

起止页码:67

中文期刊名:纺织学报

外文期刊名:Journal of Textile Research

收录:CSTPCD、、EI(收录号:20240415428303)、Scopus、CSCD2023_2024、北大核心、CSCD、北大核心2020

基金:纺织行业智能服装柔性器件重点实验室开放课题项目(SDHY2112)。

语种:中文

中文关键词:水浴静电纺丝;聚酰胺6;纳米纤维包芯纱;线状螺旋结构;电容传感器;运动监测

外文关键词:water bath electrospinning;polyamide 6;nanofiber core-spun yarn;linear spiral structure;capacitive sensor;movement monitoring

中文摘要:为获得线形螺旋结构且具有良好传感性能的大应变柔性应变-电容传感器,采用水浴静电纺丝法以镀银聚酰胺6为芯纱,制备了镀银聚酰胺6/聚酰胺6纳米纤维包芯纱,并将其缠绕在橡筋上制备应变-电容式柔性传感器。对纳米纤维包芯纱的结构与力学性能进行表征与测试,分析了应变-电容传感器的传感性能,并探索了其在人体运动监测中的应用。结果表明:聚酰胺6纳米纤维在镀银聚酰胺6表面形成结构完整的包覆层,直径分布主要在80~100 nm范围内,平均直径为95.53 nm;相较于芯纱,纳米纤维包芯纱的力学性能基本保持不变;制备的柔性传感器表现出良好的应变-电容传感性能,在6.67%的应变下敏感因子可达3.93,并具有良好的重复性,该传感器可用于人体运动的实时监测。

外文摘要:Objective Wearable technology is currently one of the most promising fields and as a key component for wearable devices,flexible sensors are crucial to the development of intelligent wearable products.Sensing performance is the only criterion for the quality of a sensor.It is of great significance to propose a new one-dimensional flexible strain-capacitive sensor with good sensing performance.Method Adopting the method of water bath electrospinning,experimental parameters were set with spinning solution concentration of 12%,electrostatic voltage of 20 kV,spinneret rate of 0.2 mL/h,core yarn winding speed of 0.16 m/min,and receiving distance of 5 cm.Silver coated polyamide 6(SCN)was chosen as the core yarn(capacitor electrode plate),and polyamide 6(PA6)nanofiber was used as the coating layer(dielectric layer)to prepare the silver coated polyamide 6/polyamide 6(SCN/PA6)nanofiber core-spun yarn,which was wound on the rubber band to prepare the strain-capacitive flexible sensor.The human knee was selected as the experimental test site,and the test subjects performed intermittent knee bending,continuous knee bending,and walking on the treadmill at different speeds,and the capacitance changes of the sensor during the movement were recorded by the capacitance tester in real time.Results By observing the structure morphology of SCN,analyzing the mechanical properties,and testing the sensing performance and practical application of the sensor,the following conclusions were obtained.PA6 nanofiber coating with complete structure was formed by electrospinning on the surface of SCN fiber(Fig.4),with a thickness of 15-20μm.The diameter distribution of nanofibers(Fig.5)was uniform,mainly in the range of 80-100 nm,with an average diameter of 95.53 nm.Compared with the core yarn,the breaking strength and elongation at break of the nanofiber core-spun yarn were slightly increased and slightly decreased(Fig.6),but the changes were small.The relative capacitance of the prepared sensor showed a decrease with the increase of elongation during stretching,while the recovery followed the opposite pattern,and the decreasing trend of the minimum capacitance gradually slows down(Fig.7).When the elongation was small(6.67%),the linear fitting equation obtained with the elongation as the independent variable and C p/C 0 as the dependent variable had a correlation coefficient as high as 0.9886(Tab.1),showing good linearity.The sensitivity of the sensor gradually decreased with the increase of the elongation.When the elongation was 6.67%,the gauge factor value reached 3.93,while when the elongation was 66.67%,the gauge factor value was only 0.90(Tab.2).The maximum C p/C 0 value of the sensor was about 1 for each stretch cycle of 450 s at different elongations,and the minimum C p/C 0 value was close to the minimum C p/C 0 value of the single stretch(Fig.9),showing good repeatability stability.The variation of stretching speed has almost no effect on the relative capacitance of the sensor.Conclusion By placing the sensor on the knee for intermittent,continuous bending and walking movements,regular and stable capacitance signal changes were obtained(Fig.11),and C p/C 0 values fluctuated stably between 0.6 and 1.0.According to the calculation and analysis of the signal changes at different speeds,the number and frequency of steps of the experimenter can be obtained(at speed of 3 km/h,the frequency is 86.4 steps/min;at speed of 4 km/h,the frequency is 107.2 steps/min;at speed of 6 km/h,the frequency is 151.8 steps/min).The strain sensor has potential applications in the field of real-time monitoring of flexible wearable human motion.It is suggested to select materials with better performance and improve the design of the structure to better play its original value.