An FPGA Based energy correction method for one-to-one coupled PET detector: model and evaluation ( SCI-EXPANDED收录 EI收录) 被引量:1
文献类型:期刊文献
英文题名:An FPGA Based energy correction method for one-to-one coupled PET detector: model and evaluation
作者:Ma, C.[1,2,4];Zhao, X.[1,2,3,4];Gao, S.[1,2];Zhang, F.[1,2];Wu, G.[1,2];Li, X.[1,2];Yu, L.[1,2];Ye, H.[1,2];Qian, H.[1,2]
机构:[1]Minfound Med Syst Co Ltd, Yifeng Rd, Hangzhou 310018, Peoples R China;[2]Zhejiang MinFound Nucl Med Imaging Res Inst, Dongshan Rd, Shaoxing 312000, Peoples R China;[3]Shaoxing Univ, Sch Med, Chengnan Rd, Shaoxing 312000, Peoples R China;[4]Univ Sci & Technol China, Modern Phys Dept, Jinzhai Rd, Hefei 230026, Peoples R China
年份:2022
卷号:17
期号:1
外文期刊名:JOURNAL OF INSTRUMENTATION
收录:SCI-EXPANDED(收录号:WOS:000757963200007)、、EI(收录号:20220611611902)、Scopus(收录号:2-s2.0-85124229952)、WOS
语种:英文
外文关键词:Digital signal processing (DSP); Electronic detector readout concepts (solid-state); Front-end electronics for detector readout; Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA)
外文摘要:A PET scanner based on silicon photomultipliers (SiPMs) has been widely used as an advanced nuclear medicine imaging technique that yields quantitative images of regional in vivo biology and biochemistry. The compact size of the SiPM allows direct one-to-one coupling between the scintillation crystal and the photosensor, yielding better timing and energy resolutions than the light sharing methods that have to be used in photomultiplier tube (PMT) PET systems. To decrease the volume of readout electronics, a front-end multiplexer with position decoder is a common choice for the one-to-one system without a highly integrated application specific integrated circuit (ASIC). However, in this case we cannot measure each crystal's deposited energy inspired by an annihilation photon, so the inter-crystal scatter (ICS) events will lead to the crystal mispositioning and then deteriorate the detector intrinsic resolution. Besides, considering the events rejection within the energy window resulting from the gain dispersion and non-linear outputs of the SiPMs, an energy correction mechanism is needed. Yet, lack of the information of each crystal's energy will introduce large energy correction error for the ICS events. For this issue, an online energy correction mechanism implemented on a Kintext-7 Field Programmable Gate Array (FPGA) device is presented in this paper. Experiments in the laboratory were performed using an 8 x 8 segmented LYSO crystals coupled with an 8 x 8 SiPM (J-series, from ON Semiconductor) array which is under Na-22 point source excitation. Test results indicate that both the energy of the non-ICS and ICS events can be precisely corrected and the energy resolution is better than 12 %. We also applied this method to an actual clinical PET scanner under a Ge-68 line source to verify its multi-channel reliability.